Where to Put a Defibrillator (AED): 10 Design Rules for Architects

By Anna Gubler-Caminiti

When a heart stops, an AED (defibrillator) can restart it. Anyone can use it: it talks and tells you what to do.

But it only saves a life if someone can find it, reach it and open it within minutes. That is a design job. Here are 10 rules for architects, urban planners and landscape architects, in four parts.

Short answer

Place a public AED within 100 m on foot of the people it serves, outside and unlocked 24/7, with the handle no higher than 122 cm, a projecting green AED sign, and register it with the ambulance service, so anyone can bring it to a person within about 3 minutes.

I. Time and distance / II. On the wall / III. Where and how high / IV. Keeping it working / Checklist / FAQ

ITime and distance

Stopwatch with the first 3 minutes marked

Fig. 1

1. Act fast

When a heart stops, time is everything. Your design decides how many minutes are lost.

  • Each minute without a shock lowers survival by 7–10%.
  • A shock within 3 minutes gives the best chance.
  • An ambulance is rarely that fast, so the AED must be close.
An AED and a person 100 metres apart, about 90 seconds on foot

Fig. 2

2. Keep it close

Distance is time. Plan the walk to the AED, not the dot on the plan.

  • A common rule: within 100 m on foot of every person.
  • That is about 90 s each way, so a 3-minute round trip.
  • Measure the walking route: rivers, roads and fences add distance.
Building front with an AED outside next to the door, open day and night

Fig. 3

3. Keep it open

A defibrillator behind a locked door is no defibrillator at all.

  • Put it outside, next to the entrance.
  • Never behind a locked door.
  • Not in staff-only rooms.

IIOn the wall

Wheelchair user reaching an AED cabinet with the handle at 122 cm

Fig. 4

4. Mount it low

Everyone must be able to reach it, including a person in a wheelchair.

  • Handle at most 122 cm above the floor.
  • Reachable from a wheelchair.
  • Keep the floor in front clear.
Wall section: the cabinet sticks out at most 10 cm between 68.5 and 203 cm

Fig. 5

5. Keep the path clear

A cabinet that sticks out is a hazard for people who cannot see it.

  • Between 68.5 and 203 cm, stick out max 10 cm.
  • Use a recessed cabinet.
  • Then people with a cane will not walk into it.
Green AED sign sticking out from the wall, its underside at least 203 cm high

Fig. 6

6. Make it visible

People in panic do not search. They must see it from far away.

  • Use the green AED sign.
  • Add a sign that sticks out from the wall.
  • Its underside at least 203 cm high.
Public defibrillator cabinets in front elevation, white backgroundDrawings for your plansPublic Defibrillator (AED) Stations in Front ViewCAD, Vector and PNG drawings · Free downloadSee the AED set →

IIIWhere and how high

Six places for AEDs: stations, shops, gyms, schools, parks and homes

Fig. 7

7. Places to start

Put AEDs where people are, and where hearts most often stop.

  • Busy places: stations, shops, gyms, schools.
  • Parks, beaches and sports grounds.
  • Homes: most arrests happen there.
Tall building with AEDs next to the lifts on several floors

Fig. 8

8. Tall buildings

In a tower, floors and lifts add minutes. Bring the AED closer.

  • Height adds time.
  • Put AEDs next to the lifts.
  • On several floors, not only the lobby.

Most cardiac arrests happen at home, not in public.

So in housing areas, place AEDs on the street and at building entrances too.

IVKeeping it working

Outdoor cabinet under a canopy, heated and lit

Fig. 9

9. Protect it outdoors

Cold, heat and rain can stop an AED from working.

  • Most AEDs work between 0 and 50 °C.
  • Use a heated cabinet in the shade.
  • Add a light for the night.
A phone call leads to the nearest registered AED

Fig. 10

10. Register it

A registered AED can be found by the emergency service, and by the caller.

  • Register it with the ambulance service or national AED network.
  • Then the call handler can send a caller to it.
  • Name a person who checks the light, pads and battery.

Outside, close, low, visible and registered.

So anyone can bring it to a person within 3 minutes.

Checklist

Tick each item as you check your drawings. To draw the AEDs, use our free AED stations set.

Questions architects ask

How far apart should public AEDs be?+

About 100 m on foot

A common planning rule is that nobody should be more than about 100 m on foot from an AED. That is about 90 seconds each way, so someone can fetch it and come back within about 3 minutes.

At what height should an AED cabinet be mounted?+

Handle at most 122 cm

Keep the handle no higher than 122 cm (48 in) above the floor, so a wheelchair user can reach it. This follows the US ADA Standards; check your local code.

Can an AED cabinet stick out from the wall?+

At most 10 cm

Between 68.5 and 203 cm above the floor it should stick out no more than 10 cm, so people with a white cane do not walk into it. Use a recessed or semi-recessed cabinet.

Should a public AED be inside or outside?+

Outside, open 24/7

Outside, next to the main entrance, unlocked and available 24/7. An AED inside a building that is closed is not available when it is needed.

Does an outdoor AED need a heated cabinet?+

Usually, yes

Usually yes in cold or hot climates. Most AEDs work between about 0 and 50 °C, so use a heated, ventilated cabinet out of direct sun, with lighting.

Where should AEDs go in tall buildings?+

By the lifts, on several floors

Next to the lifts on several floors, not only in the ground floor lobby. Lifts and stairs add minutes, and survival is lower on higher floors.

Heights follow the US ADA Standards. Rules differ by country: always check your local codes.

Spotted a mistake? Tell us and we will check and fix it.Report an error